Solar Power for a Shed or Workshop
By Matt · Updated
The short answer
A shed with lighting and battery charging needs surprisingly little: a few hundred watts of panel and a small bank. What breaks these systems is not daily energy at all, it is the startup surge of a corded power tool, which sizes the inverter far above what the running watts suggest.
The worked system
A detached workshop used a few evenings a week and most weekends. Lighting, charging tool batteries, a radio, and occasional corded tool use. No heating, no fridge.
Daily loads
| Load | Watts | Hours | Duty | Wh/day |
|---|---|---|---|---|
| LED shop light ×4 | 20 | 3 | 1 | 240 |
| Tool battery charger | 90 | 1.5 | 1 | 135 |
| Radio | 15 | 3 | 1 | 45 |
| Phone and device charging | 12 | 2 | 1 | 24 |
| Circular saw (occasional) | 1,400 | 0.15 | 1 | 210 |
| Total | 654 Wh | |||
What that needs
- Solar array
- 272 W
- Battery bank
- 255 Ah at 12 V
- Usable storage
- 2.0 kWh
- Charge controller
- 28 A minimum
- Inverter, continuous
- 2,000 W
- Must also surge to
- 3,697 W
An inverter has two ratings and both have to hold. The continuous figure covers everything running at once; the surge figure covers the largest motor starting on top of that, for a few seconds. Most inverters surge to roughly twice their continuous rating, but check the specification rather than assuming, because an inverter that cannot supply the surge will not start the appliance at all.
Sized on 3 peak sun hours, 3 days of autonomy, and LiFePO4 at its recommended depth of discharge. The bank includes a 25% margin for inverter losses, cold weather, and aging.
Every figure above is computed by the same calculators this site publishes, not typed in. To change any assumption, put your own numbers into the appliance power budget and the system sizing calculator.
A shed or workshop is the easiest off-grid system to get right, and a good first build. The loads are small, nothing is critical, and if it runs out you simply come back tomorrow. Nobody is left in the dark in February because you got the arithmetic wrong.
It is also the system where people most often buy the wrong inverter.
Why the inverter is the interesting part
Look at the load table above. The circular saw uses barely any energy, because you are cutting for minutes rather than hours. It contributes almost nothing to the daily watt-hour total, which is what sizes the panels and battery.
But it needs an inverter several times larger than everything else combined. A universal motor under load draws far more current starting than running, and an inverter that cannot supply that surge will simply shut down or fail to start the tool at all.
This is the general lesson for outbuildings: the daily energy figure sizes the array and the bank; the worst instantaneous load sizes the inverter. They are different questions with different answers, and a system sized only on the first will disappoint the first time you pick up a saw.
If your workshop will see a table saw, an air compressor, or a welder, price the inverter for those before anything else. It will likely be the largest single cost in the build.
Where the energy actually goes
Lighting dominates, which surprises people who assume the tools do. Four shop lights running three hours is more energy than a saw uses all week.
That makes lighting the first place to economize. Modern LED shop lights draw a fraction of what fluorescent tubes did, and in a workshop you rarely need every fixture on at once. Switching banks separately is a cheap way to cut the largest load on the system.
Three days of autonomy on purpose
The scenario above uses three days rather than the two a cabin would typically get. That is not because a shed matters more. It is because a shed gets used irregularly, often in bursts, and often in winter.
A workshop system that is dead when you walk in on a Saturday morning in January is useless in a way a cabin system that runs slightly short is not. Storage is cheap at this scale, so buying the extra day is easy.
Practical notes for an outbuilding
Mount the array where you can reach it. A shed roof is usually low enough to clear snow from the ground with a brush, which is a real advantage over a house roof.
Watch the cable run from the array. A ground mount twenty feet away at 12 V needs heavier cable than people expect. Run the numbers through the wire gauge calculator before buying wire, and remember it wants the one-way distance.
Keep the batteries inside the building, insulated. A shed is usually unheated, and a bank at freezing delivers meaningfully less than it does at room temperature. If you are using LiFePO4, confirm how it handles charging below freezing.
Fuse at the battery. A small system is not a safe system by default. The bank can still deliver hundreds of amps into a short. See battery safety.
If you want to change any of this
The specification above is computed from the load list, not written by hand. Your workshop will not have exactly these loads, so put your own into the appliance power budget, then feed the daily total into system sizing with the sun hours for your location.
Two inputs move the answer more than anything else: peak sun hours in your worst month, and whether you run a large motor.
Common questions
- Can I run power tools off a small solar system?
- Yes, if you size the inverter for the startup surge rather than the running watts. A circular saw drawing 1,400 W running can spike to 3,000 W or more starting. The energy used is trivial because the cuts are short; the inverter has to survive the surge.
- Do I need a battery, or can I run straight from panels?
- You need a battery. Panel output varies constantly with cloud, and a tool would stall or an LED flicker every time the sun went behind something. The battery smooths that out and lets you work after dark.
- Is 12 V the right choice for a shed?
- Usually yes, at this size. The array is small enough that cable costs stay reasonable, and 12 V equipment is cheap and widely available. If you plan to add heating or a compressor later, work out the wire sizes at 24 V before committing.
- What about winter, when I use the lights most?
- That is the real constraint. Shed use peaks in the dark months when the array produces least, so size on December sun hours rather than an annual average, and consider a way to charge from mains occasionally if the building is near the house.